Proven Pre-engineered Wastewater System

The TrojanUV3000®PTP (Packaged Treatment Plant) is ideally suited to treat flows up to 3 MGD (473 m3/hr). It is pre-engineered for quick, economical installation and is designed with proven components to provide a dependable UV solution for small wastewater treatment applications.

Key Features and Benefits

Flexible Installation Options

The TrojanUV3000PTP can be installed into existing chlorine contact tanks and effluent channels. It comes pre-tested, pre-assembled and pre-wired to minimize installation costs, and can also be equipped with prefabricated stainless-steel channels with built-in weirs. Channels are easily integrated with existing flanged piping using transition boxes.

TUV3000PTP-System-780x390
Key Features and Benefits

Compact Modules

Space-saving electronic lamp drivers are housed right in the modules, not in separate external cabinets – this minimizes the footprint of the UV system and eliminates the need for air-conditioning. Lamp drivers are cooled by convection and each UV module includes a UV lamp status indicator for at-a-glance monitoring.

ballast-grey-background.png
Compact Modules

Operator-friendly Maintenance

Modules are lightweight and can be individually removed for periodic sleeve cleaning and lamp change-outs. An optional mobile cleaning rack simplifies maintenance procedures.

TUV3000PTP-Maintenance-square-gray
Operator-friendly Maintenance

Proven Performance, Components and Design

The TrojanUV3000PTP has been validated through microbial testing. Through this testing, performance data has been generated for UV dose delivery to inactivate microorganisms Escherichia coli (E. coli ) and fecal coliform.

TUV3000PTP-Module Channel-square-gray
Proven Performance, Components and Design

Is your wastewater treatment plant's flow rate 3 to 5 MGD?

If so, the TrojanUV3000®B is another option you should consider.

System Specification

System Characteristics

Typical Applications

Up to 3 MGD (473 m3/hr)

Lamp Type

Low-pressure

Lamp Driver Type

Electronic; non-variable

Input Power Per Lamp

45 or 87.5 Watts

Lamp Configuration

Horizontal, parallel to flow

Module Configuration

2 or 4 lamps per module

Bank Configuration

Up to 10 modules per bank

Channel Configurations

Lamp Banks in Series

Up to 2

Channel Options

Stainless Steel (Trojan option) or Concrete (by others)

Flanged Transition Connections

Optional for stainless steel channels

U-Turn Connector Box

Level Control Device Options

Fixed weir

Enclosure Ratings

System Monitor/Control Center

Fibreglass

Lamp Driver Enclosure

TYPE 6P (IP67)

Lamp Driver Cooling Method

Convection; no air conditioning or forced air required

Installation Location

Indoor or outdoor

System Monitoring & Controls

Controller

Optional; Monitoring only

UV Intensity Monitoring

Optional

Inputs Required

None

Local Status Indication

Lamp Age (hours) UV Intensity (mW/cm2)

Remote Alarms

UV Intensity (4-20 mA)

Location

Indoor or outdoor

Maximum Distance from UV Channel

15 ft. (4.5 m)

Electrical Requirements

UL System

CE System

Power Distribution

Individual GFI Receptacles for UL system

Receptacle provided by third-party with outdoor-rated, 16 Amps, 220-250 Volt, 3 poles in compliance with local electrical code

Quantity Required

1 receptacle per 2 modules for UL system

CE system determined by third-party electrical code

Power Input

120V, single phase for UL system

230V, single phase for CE system

Related Resources

PROM-Literature-3000PTP-280x280

TrojanUV3000PTP Brochure

Complete product overview of the TrojanUV3000PTP system, covering applications, key features and benefits, and technical specifications.

Service-Parts-BrochureTHUMB-2026

TrojanUV Service & Parts Brochure

TrojanUV is here to help you every step of the way, from system inspections, repairs, training and preventative maintenance to upgrades and genuine replacement parts.

TrojanUV3000PTP Replacement Parts

Genuine parts help to ensure proper operation and maintenance of your TrojanUV system.